96,433 research outputs found

    Self-Organized Criticality in a Bulk Driven One-Dimensional Deterministic System

    Full text link
    We introduce a deterministic self-organized critical system that is one dimensional and bulk driven. We find that there is no universality class associated with the system. That is, the critical exponents change as the parameters of the system are changed. This is in contrast with the boundary driven version of the model [M. de Sousa Vieira, Phys. Rev. E 61 (2000) 6056] in which the exponents are unique. This model can be seen as a discretized version of the conservative limit of the Burridge-Knopoff model for earthquakes.Comment: In honor of Constantino Tsallis in the celebration of his 60th birthday (5 pages, 3 figures)- corrected typo

    The application of cogeneration systems to the cooling of food and buildings in East Timor : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology at Massey University

    Get PDF
    Cogeneration is generation of both heat and power simultaneously using a single primary energy input. Cogeneration recovers "waste heat "from a conventional power generation plant to produce useful energy, leading to the increased overall efficiency of fuel input. This also achieves cost savings, and reduces greenhouse gas emissions where fossil fuels are used. The objectives of this study are to assess the technical and economic viability of a cogeneration system for the cooling of food and buildings in East Timor. The findings of this research provide a basis for recommending action and further research to East Timor's decision-makers on energy issues. Technical assessments in this study focus on cooling, electricity demand, and fuel supply as the basis for choosing the type and size of a cogeneration system. The financial viability of the cogeneration system is assessed using net present value (NPV) and sensitivity analysis. The NPV of the cogeneration system is compared with the NPV of conventional energy supply for cooling and electricity. There is low demand for cooling for comfort and food preservation in East Timor, due to low levels of industrial and commercial investment, and the vast majority of people still living in poverty. Although cooling demand is low overall, numerous government and commercial buildings have installed cooling systems. In this study, six buildings (2 office buildings, a bank, a hotel, a university and a mini-market) were selected based on their relatively high cooling demand and their geographic proximity to one another. The cooling demand of these six buildings was modeled based on a room-by- room approach. The results showed that their overall hourly cooling demand averages 600 kilowatt-cooling, while peak load was 707 kilowatt-cooling. This cooling demand was primarily driven by ambient temperature, number of people present and lighting load. Power demand in East Timor is low. The total operable power supply capacity for the entire country is 22 megawatts, of which more than half is located in Dili. Electricity demand is predominantly driven by residential consumption, rather than commercial and industrial consumption. Although there is low electricity demand, East Timor faces an immediate electricity deficit of 24 megawatts, which is higher than the existing operable capacity. In the six selected buildings, the overall peak and average electricity loads were 489 kW and 422 kW respectively. This load was mainly driven by air conditioning, computers, and lighting applications during working hours. Electricity generation relies on diesel, which is imported from Indonesia. Diesel will remain the main source to generate electricity due to a lack of feasible alternatives. East Timor is rich in natural gas both offshore and onshore. However, until now there has been no plan to provide natural gas distribution pipelines to East Timor. Based on the cooling and electricity demand and fuel availability, diesel was chosen to drive the cogeneration systems. The size of the cogeneration system was selected so as to fulfill both the electricity demand in the six selected buildings and be able to export surplus to the local grid. There are two reasons for employing a larger engine capacity. Firstly, a small engine will not be able to generate sufficient heat to drive an absorption cooling system with a capacity of 600 kilowatt. Secondly, export electricity will increase revenues generated from the cogeneration plant. Financially, the net present value (NPV) of both the cogeneration system and the conventional energy supply system were lower than zero, which means that neither system can be viable financially. The cogeneration system's NPV was lower than that for the conventional energy supply system, due to its higher capital and operating costs. High operating costs were due to fuel costs, with low revenues being due to heavy subsidies on electricity. If fuel and electricity subsidies were removed, a cogeneration system could become a more attractive option compared to a conventional system. However, removing the electricity subsidy would result in the large majority of people being unable to afford electricity

    Dangling-bond spin relaxation and magnetic 1/f noise from the amorphous-semiconductor/oxide interface: Theory

    Full text link
    We propose a model for magnetic noise based on spin-flips (not electron-trapping) of paramagnetic dangling-bonds at the amorphous-semiconductor/oxide interface. A wide distribution of spin-flip times is derived from the single-phonon cross-relaxation mechanism for a dangling-bond interacting with the tunneling two-level systems of the amorphous interface. The temperature and frequency dependence is sensitive to three energy scales: The dangling-bond spin Zeeman energy delta, as well as the minimum (E_min) and maximum (E_max) values for the energy splittings of the tunneling two-level systems. We compare and fit our model parameters to a recent experiment probing spin coherence of antimony donors implanted in nuclear-spin-free silicon [T. Schenkel {\it et al.}, Appl. Phys. Lett. 88, 112101 (2006)], and conclude that a dangling-bond area density of the order of 10^{14}cm^{-2} is consistent with the data. This enables the prediction of single spin qubit coherence times as a function of the distance from the interface and the dangling-bond area density in a real device structure. We apply our theory to calculations of magnetic flux noise affecting SQUID devices due to their Si/SiO_2 substrate. Our explicit estimates of flux noise in SQUIDs lead to a noise spectral density of the order of 10^{-12}Phi_{0}^{2} {Hz}^{-1} at f=1Hz. This value might explain the origin of flux noise in some SQUID devices. Finally, we consider the suppression of these effects using surface passivation with hydrogen, and the residual nuclear-spin noise resulting from a perfect silicon-hydride surface.Comment: Final published versio
    • …
    corecore